RadCalc® QA software performs independent MU or point dose verification calculations for both 3D and IMRT Treatment Planning Systems including MLC, Diode and EDW support. Full automation available utilizing Import and Export utilities for TPS and R & V systems. Software package includes setup, installation, training, and hardcopy printouts for billing and patient documentation. |
|
RadCalc Applications
RadCalc Features
|
Publications
- "Revision of Tissue-Maximum Ratio and Scatter Maximum Ratio Concepts for Cobalt 60 and Higher Energy X-Ray Beams"
Medical Physics 7, 230-237 (1980) - "Off center ratios for three-dimensional dose calculations"
Medical Physics, 13 (3), pp. 409-412, (1986) - "Dose computations for asymmetric fields defined by independent jaws"
Medical Physics, 15 (1), pp. 92-95, (1988) - "A Modified Power-Law Formula for Inhomogeneity Corrections in Beams of High Energy X-Rays"
Medical Physics 18, 719-723 (1991) - "Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee
Task Group 40"
Medical Physics, 21, pp. 581-618, (1994) - "Comprehensive analysis of electron beam central axis dose for a radiotherapy linear accelerator"
Medical Physics, 21, pp. 559-566, (1994) - "Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43"
Medical Physics, 22, pp. 209-234, (1995) - "Using the field edge correction (FEC) method to generate accurate POCRs and OCRs
for asymmetric fields"
Medical Physics, 23 (3), pp. 353-356, (1996) - "Calculation of enhanced dynamic wedge factors for symmetric and asymmetric photon fields"
Medical Physics, 25, 1411-1418, (1998) - "A generalized solution for the calculation of in-air output factors in irregular fields"
Medical Physics, 25 (9), pp. 1692-1701, (1998) - "A Monitor Unit Verification Calculation in Intensity Modulated Radiotherapy as a
Dosimetry Quality Assurance"
Medical Physics, 27, 2226-2230, (2000) - "Implementation and verification of Virtual Wedge in a three-dimensional
radiotherapy planning system"
Medical Physics, 27 (7), pp. 1635-1643, (2000) - "A sector-integration method for calculating the output factors of irregularly shaped electron fields"
Medical Physics, 24, pp. 1765-1769, (2000) - "Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for
brachytherapy dose calculations"
Medical Physics, 31, pp. 633-674, (2004) - "Supplement to the 2004 update of the AAPM Task Group No. 43 Report"
Medical Physics, 34, pp. 2187-2205, (2007) - "Monitor Unit Comparison Between a Treatment Planning System and an Independent Monitor Unit Calculation Software"