With ArcCHECK, see the entire picture
ArcCHECK is the world‘s first true 4D detector array, cylindrical detector array, and electronic array designed specifically for
rotational dosimetry.Below is what a 2D array and ArcCHECK will see for the same plan measurement. Unrolling ArcCHECK dose makes it possible to see much more, highlighting areas that would not normally be seen with a 2D array.

Key Benefits
- SunPoint™ Diode Detectors for accurate measurements
- Virtual Inclinometer™ for gantry angle QA [image]
- Internal Inclinometer for ease of setup [image]
- 3D and DVH Analysis
- Easy setup and lightweight (16kg)
- Measure both composite and per control point
- Real-time updates (50ms)
Hardware

Features and Specifications

Publications
Recommended Reading
- "Pretreatment quality assurance of flattening filter free beams on
224 patients for intensity modulated plans: A multicentric study"
Stephanie Lang, Jan Hrbacek, and Stephan Klöck. Med. Phys. 39, 1351 (2012)
-
"Use of a 3D Diode Array System (ArcCHECK) to Perform Routine IMRT QA and Patient Dose Verification"
JM. Zifodya, M. Saberi, A. Morris, Plymouth Hospital NHS Trust
-
"Plan Verification Using Semiconductor Based 3D Detector For Rotational IMRT"
G Chinnusamy, M Manikowski, K Kleinert, T Müdder, Y Nour, F Schoroth, S Arican, G A Zakaria, S Garbe
Additional Publications
- "Pretreatment quality assurance of flattening filter free beams on
224 patients for intensity modulated plans: A multicentric study"
Med. Phys. 39, 1351 (2012)
- "The ArcCHECK diode array for dosimetric verification of HybridArc"
Phys. Med. Biol. 56 5411 (2011)
- "Optimizing the accuracy of a helical diode array dosimeter: A comprehensive
calibration methodology coupled with a novel virtual inclinometer"
Med. Phys. 38, 5021 (2011)
- WE-C-BRB-11: "Four Dimensional Analysis of VMAT Delivery"
Med. Phys. 38, 3806 (2011)
- SU-E-T-185: "Passing Rates of 83 Patient-Specific IMRT QA Measurements with ArcCHECK Using Various Gamma Criteria"
Med. Phys. 38, 3528 (2011)
- SU-E-T-181: "IMRT Quality Assurance -Evolution from 2D to 3D"
Med. Phys. 38, 3528 (2011)
- SU-E-T-547: "ArcCHECK Diode Array for Dosimetric Verification of HybridArc"
Med. Phys. 38, 3615 (2011)
- SU-E-T-190: "Measuring Patient Cone Beam CT Dose Using a Commercial 4D Diode Array"
Med. Phys. 38, 3530 (2011)
- SU-E-T-212: "Measurement Comparison and Monte Carlo Analysis for Rapid Arc Delivery Verification Using ArcCheck Dosimetry System"
Med. Phys. 38, 3535 (2011)
- SU-E-T-429: "Clinical Use of ArcCHECK for IMRT and VMAT Delivery QA"
Med. Phys. 38, 3587 (2011)
- SU-E-T-154: "Evaluation and Improvement of the ArcCHECK 3D Dosimeter"
Med. Phys. 38, 3521 (2011)
- SU-E-T-185: "Passing Rates of 83 Patient-Specific IMRT QA Measurements with ArcCHECK Using Various Gamma Criteria"
Med. Phys. 38, 3528 (2011)
- WE-C-BRB-11: "Four Dimensional Analysis of VMAT Delivery"
Med. Phys. 38, 3806 (2011)
- SU-E-T-92: "The Field Size Dependence of the ArcCheck 4D Diode Array and Its Correction Strategy"
Med. Phys. 38, 3507 (2011)
- WE-E-BRB-04: "VMAT Dynamic QA for Moving Lung Tumors"
Med. Phys. 38, 3816 (2011)
- SU-E-T-413: "Optimizing the Delivery of Intensity-Modulated Stereotactic Body Radiation Therapy to Lung Tumours Influenced by Respiratory Motion"
Med. Phys. 38, 3583 (2011)
- SU‐DD‐A1‐03: "On Rotational Measurements with the ArcCHECK 3D Diode Array"
Med. Phys. 37, 3088 (2010)
- SU‐GG‐T‐239:" Initial Experience of Patient Specific Rotational Quality Assurance for VMAT Using a Cylindrical Diodes Array Detector System"
Med. Phys. 37, 3240 (2010)
- SU‐GG‐T‐360: "Investigation of TomoTherapy Patient Specific Delivery Quality Assurance (DQA) Using a Cylindrical Diodes Array Detector System"
Med. Phys. 37, 3269 (2010)
- SU‐GG‐T‐244: "3‐Dimensional Dosimetry QA Evaluation for Volumetric Modulated Arc Therapy"
Med. Phys. 37, 3241 (2010)
- SU‐DD‐A1‐02: "The X's and O's of 3D Dosimetry Phantoms"
Med. Phys. 37, 3088 (2010)
- SU‐GG‐T‐245: "3‐Dimensional Dosimetry QA Evaluation for Volumetric Modulated Arc Therapy"
Med. Phys. 37, 3241 (2010)
- SU‐GG‐T‐242: "Sensitivity Analysis of Single and Partial Arc Plans for VMAT Planning, Delivery and QA"
Med. Phys. 37, 3241 (2010)
- "Calibration of a novel four-dimensional diode array"
Med. Phys. 37, 108 (2010)
- MO‐FF‐A1‐02: "Calibration of a Novel 4D Diode Array for IMRT and VMAT QA"
Med. Phys. 36, 2708 (2009)
-
"Use of a 3D Diode Array System (ArcCHECK) to Perform Routine IMRT QA and Patient Dose Verification"
-
"Plan Verification Using Semiconductor Based 3D Detector For Rotational IMRT"
-
"Evaluation of a Helical Diode Array Device for IMRT Quality Assurance"
-
"Evaluation of the Use of ArcCHECK for RapidArc Quality Assurance"
-
"Initial Experience of Patient Quality Assurance for RapidArc using ArcCHECK at HOPE, Guatemala"
-
"Dosimetric Evaluation of a 3D Dosimeter for Helical TomoTherapy"
-
"Evaluation of a Commercial 4D Diode Array for Helical TomoTherapy Plan Verification"