MapCHECK® 3 is the gold standard for IMRT QA requiring large field measurements. It offers the highest detector density, highest sensitivity, and largest field size of 2D arrays. Plus, it's uniquely TG 218-compliant.
Built for Pre-Treatment IMRT QA
SunPoint® 2 Diode Detectors placed uniformly throughout the array offer high sensitivity and proven stability in a large active field size (26 cm x 32 cm). A real-time electrometer measures every pulse with 50-millisecond updates.
Easy Comparison Features
Simply import the QA files from your TPS, and let SNC Patient™ software compare dose distribution from the plan file to actual measured values. Measured points outside of acceptance criteria are highlighted for high and low dose.
See why MapCHECK 3 is the chosen solution for IMRT QA.
 
						Address Rotational Beams
Use MapCHECK 3 with MapPHAN™, a water equivalent phantom, for RapidArc®, VMAT, and TomoTherapy®. Setup time is fast and measurement can occur in coronal and sagittal orientations.
 
						Quick Start Features
Portable and lightweight array with no warm-up or pre-irradiation necessary for use
 
						Easy Annual Calibration
Patented Wide Field Calibration step-by-step instructions are included in SNC Patient™ software, for a 15-minute annual calibration.
 
						Isocentric Mounting Fixtures
GMF™ and IMF™ Mounting Fixtures mount the MapCHECK 3 to the head of the gantry for quick, reproducible isocentric measurements at any gantry angle.
 
						SNC Patient™ Software
Import QA files from TPS, and SNC Patient compares dose distribution of plan file to actual measured values. Points outside acceptance criteria are clearly highlighted.
Resources
 
						Webinars & Videos
 
						Downloads
Specifications
| Detector Type | SunPoint® 2 Diode Detectors | 
| Detector Quantity | 1,527 | 
| Field Size (cm) | 26 x 32 | 
| Detector Spacing (mm) | 7.07 | 
| Active Detector Area (mm x mm) | 0.48 x 0.48 | 
| Active Detector Volume (mm3) | 0.007 | 
| Detector Sensitivity (nC/Gy) | 15 | 
| Sampling Frequency (ms) | 50 | 
| Detector Stability | 1%/kGy at 6 MV | 
| Dose Rate Dependence | ±1.5% over the range of 100 cGy/min to 1400 cGy/min | 
| Inherent Buildup (g/cm2) | 1.5 | 
| Inherent Backscatter (g/cm2) | 2.3 | 
| Radiation Measured | Photons: Co-60 to 25 MV | 
| Number of Connection Cables | Single power/data cable | 
| Dimensions (L/W/H) | 56.0 cm x 29.2 cm x 3 cm | 
| Weight (kg) | 5.6 | 
| MoreLess | |
| Operating System | Windows 7, Windows 8.1, Windows 10 Professional | 
| CPU | Recommended 2.4 GHz or better, multi‑core (2 or more cores) | 
| RAM | Recommended 4 GB or more | 
| Hard Drive Space | Recommended 5 GB or more | 
| Rotational Therapy | RapidArc®, VMAT, TomoHelical™ IMRT, TomoDirect™, 3D Conformal, Dynamic Wedge | 
| Treatment Planning Systems | Pinnacle®, Eclipse®,Monaco®, iPlan®, and any TPS system that can export DICOM data | 
| Deliveries | FFF & non-FFF | 
 